Nowadays, people's living standards are improving and their power consumption is also increasing. How to better understand their power consumption? It is necessary to install an electricity meter to understand the power consumption, but the electricity meter can not be installed casually. Reasonable and safe installation is the most important! We all know that everyone has his own home, and the meter also has his own home! The meter box is the warm "home" of the meter!


1. In principle, the electric energy metering assembly for trade settlement shall be set at the property right boundary of power supply and consumption facilities; At the other end of the power generation enterprise's on grid line, the connecting line between power grid operation enterprises and the special line power supply line, the assessment electric energy metering assembly shall be set.


2. The electric energy metering assembly for class I, II and III trade settlement shall be equipped with special voltage and current transformers or special secondary windings according to the metering points. Special voltage and current transformers or special secondary windings and their secondary circuits for electric energy metering shall not be connected to equipment irrelevant to electric energy metering.


3. Two sets of active energy meters with the same accuracy grade should be configured for the electric energy metering assembly for measuring the on-line trade settlement energy of generator units with single unit capacity of 100MW and above and the electric energy metering assembly for purchasing and selling energy among power grid operation enterprises.


4. The secondary circuit of voltage transformer in the electric energy metering assembly for trade settlement above 35kV shall not be equipped with isolating and disconnecting auxiliary contacts, but fuses can be installed; The secondary circuit of voltage transformer in the electric energy metering assembly for trade settlement of 35kV and below shall not be equipped with isolating and disconnecting auxiliary contacts and fuses.


5. The electric energy metering assembly for trade settlement installed at the user's place, and the users with voltage of 35kV and below shall be equipped with electric energy metering cabinet or electric energy metering box of the same national standard; Users of kva20 voltage power supply should be equipped with electric energy metering cabinet or electric energy metering box of the same national standard.