Certificates | CE |
Electric ratings | AC50/60Hz, 690V, up to 95A |
Application | remote making breaking circuits, protect circuit from over-load when assembling with thermal over-load relay, frequent start-up and control of Ac motor |
Utilization category | AC-3, AC-4 |
Altitude | ≤2000m |
Ambient temperature | :-5℃-+40℃ |
Mounting category | III |
Mounting conditions | inclination between the mounting plane and the vertical plane should not exceed±5° |
Standard | IEC/EN 60947-4-1 |
Availability: | |
---|---|
Quantity: | |
item | Model | CJX2-09(Z) | CJX2-12(Z) | CJX2-18(Z) | CJX2-25(Z) | CJX2-32(Z) | |
Pole | 3 / 4 | 3 / 4 | 3 | 3 / 4 | 3 | ||
Auxiliary Contact | 1NO/1NC | 1NO/1NC | 1NO/1NC | 1NO/1NC | 1NO/1NC | ||
Rated conventional heating current(A)AC | 20 | 20 | 30 | 40 | 50 | ||
Rated operational current(A) | 380/400V | AC-3 AC-4 | 9 | 12 | 18 | 25 | 32 |
3.5 | 5 | 7.7 | 8.5 | 12 | |||
660/690V | AC-3 AC-4 | 6.6 | 8.9 | 12 | 18 | 21 | |
1.5 | 2 | 3.8 | 4.4 | 7.5 | |||
Rated insulation voltage(V AC) | 690 | 690 | 690 | 690 | 690 | ||
Power of controlled 3-phase cage motor(AC-3) | kW | 220/230V AC 380/415V AC 660/690V AC | 2.2 | 3 | 4 | 5.5 | 7.5 |
4 | 5.5 | 7.5 | 11 | 15 | |||
5.5 | 7.5 | 10 | 15 | 18.5 | |||
AC coil(V) | 24,36,48,110,127,220,240,380,415,440,480,500,600 | ||||||
DC coil(V) | 24,36,48,110,220 | ||||||
Items | Model | CJX2-40(Z) | CJX2-50(Z) | CJX2-65(Z) | CJX2-80(Z) | CJX2-95(Z) | |
Pole | 3 / 4 | 3 / 4 | 3 / 4 | 3 / 4 | 3 / 4 | ||
Auxilirary Circuit Cat:AC-15,Ue=415V Ie=0.95A Ith=10A | 1NO+1NC | 1NO+1NC | 1NO+1NC | 1NO+1NC | 1NO+1NC | ||
Rated conventional heating current (A)Ac-1 | 60 | 80 | 80 | 125 | 125 | ||
Rated operational current(A) | 380/400V | AC-3 AC-4 | 40 | 50 | 65 | 80 | 95 |
18.5 | 24 | 28 | 37 | 44 | |||
660/690V | AC-3 AC-4 | 34 | 39 | 42 | 49 | 49 | |
9 | 12 | 14 | 17.3 | 21.3 | |||
Rated insulation voltage (V AC) | 690 | 690 | 690 | 690 | 690 | ||
Power of controlled 3-phase cage motor(AC-3) | kW | 220/230V AC 380/415V AC 660/690V AC | 11 | 15 | 18.5 | 22 | 25 |
18.5 | 22 | 30 | 37 | 45 | |||
30 | 37 | 37 | 45 | 45 | |||
AC coil(V) | 24,36,48,110,127,220,240,380,415,440,480,500,600 | ||||||
DC coil(V) | 24,36,48,110,220 |
item | Model | CJX2-09(Z) | CJX2-12(Z) | CJX2-18(Z) | CJX2-25(Z) | CJX2-32(Z) | |
Pole | 3 / 4 | 3 / 4 | 3 | 3 / 4 | 3 | ||
Auxiliary Contact | 1NO/1NC | 1NO/1NC | 1NO/1NC | 1NO/1NC | 1NO/1NC | ||
Rated conventional heating current(A)AC | 20 | 20 | 30 | 40 | 50 | ||
Rated operational current(A) | 380/400V | AC-3 AC-4 | 9 | 12 | 18 | 25 | 32 |
3.5 | 5 | 7.7 | 8.5 | 12 | |||
660/690V | AC-3 AC-4 | 6.6 | 8.9 | 12 | 18 | 21 | |
1.5 | 2 | 3.8 | 4.4 | 7.5 | |||
Rated insulation voltage(V AC) | 690 | 690 | 690 | 690 | 690 | ||
Power of controlled 3-phase cage motor(AC-3) | kW | 220/230V AC 380/415V AC 660/690V AC | 2.2 | 3 | 4 | 5.5 | 7.5 |
4 | 5.5 | 7.5 | 11 | 15 | |||
5.5 | 7.5 | 10 | 15 | 18.5 | |||
AC coil(V) | 24,36,48,110,127,220,240,380,415,440,480,500,600 | ||||||
DC coil(V) | 24,36,48,110,220 | ||||||
Items | Model | CJX2-40(Z) | CJX2-50(Z) | CJX2-65(Z) | CJX2-80(Z) | CJX2-95(Z) | |
Pole | 3 / 4 | 3 / 4 | 3 / 4 | 3 / 4 | 3 / 4 | ||
Auxilirary Circuit Cat:AC-15,Ue=415V Ie=0.95A Ith=10A | 1NO+1NC | 1NO+1NC | 1NO+1NC | 1NO+1NC | 1NO+1NC | ||
Rated conventional heating current (A)Ac-1 | 60 | 80 | 80 | 125 | 125 | ||
Rated operational current(A) | 380/400V | AC-3 AC-4 | 40 | 50 | 65 | 80 | 95 |
18.5 | 24 | 28 | 37 | 44 | |||
660/690V | AC-3 AC-4 | 34 | 39 | 42 | 49 | 49 | |
9 | 12 | 14 | 17.3 | 21.3 | |||
Rated insulation voltage (V AC) | 690 | 690 | 690 | 690 | 690 | ||
Power of controlled 3-phase cage motor(AC-3) | kW | 220/230V AC 380/415V AC 660/690V AC | 11 | 15 | 18.5 | 22 | 25 |
18.5 | 22 | 30 | 37 | 45 | |||
30 | 37 | 37 | 45 | 45 | |||
AC coil(V) | 24,36,48,110,127,220,240,380,415,440,480,500,600 | ||||||
DC coil(V) | 24,36,48,110,220 |