The stability of rural power grids in Africa is poor, and frequent power outages and instantaneous power restoration can easily cause surge currents, coupled with overhead line induced lightning strikes and line operation overvoltages, which can easily cause MCB tripping, electronic drive burnout, and damage to lighting power supplies. A combination scheme is needed for lighting electrical ready boards to resist the impact.
The lighting electrical ready board is equipped with a secondary surge protector SPD (Type 2), which is connected in parallel to the incoming line and specifically designed to deal with microsecond level transient high voltage surges, including line switching spikes and induced lightning overvoltage. Many stations in Africa have poor grounding conditions, and SPDs must be equipped with SCB backup protection to avoid aging, short circuits, and fires; SPD only clamps instantaneous high voltage and cannot limit continuous closing surge. It needs to be coordinated with a delay protector and cannot be relied on alone.
The selection of components in the lighting electrical ready board should also be adapted to the working conditions. The C-curve is preferred for the incoming MCB, as it can withstand larger short-term surge currents and reduce false tripping caused by inrush currents. Reasonable grouping of lighting branches, setting up branch power on time when conditions permit, staggering the charging peak of each group of driving power sources, and dispersing inrush current. The grounding of the lighting electrical ready board should prioritize the use of the nearest grounding electrode to ensure smooth SPD discharge channels; Shorten the length of SPD leads and reduce the residual voltage rise caused by lead inductance.
At the maintenance level, local operation and maintenance capabilities are taken into account, and wide voltage, high humidity and weather resistant models are selected for components to reduce debugging requirements. The complete protection logic is clear: delayed closing staggered synchronous surge current, SPD absorbs instantaneous high voltage spikes, and C-type circuit breakers withstand short-term impacts. This solution is suitable for the environment of high power supply fluctuations and weak operation and maintenance in rural Africa, effectively reducing the failure rate of lighting power supplies and electrical ready board components, and minimizing on-site repairs.